Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Quantitation of solifenacin in human plasma using a specific and sensitive liquid chromatography-tandem mass spectrometry technique

Wesam G Ammari

Faculty of Pharmacy and Medical Sciences, Al-Ahliyya Amman University, Jordan;

For correspondence:-     Email: wammari@ammanu.edu.jo   Tel:+962777488028

Received: 6 January 2015        Accepted: 22 April 2015        Published: 26 May 2015

Citation: Ammari WG. Quantitation of solifenacin in human plasma using a specific and sensitive liquid chromatography-tandem mass spectrometry technique. Trop J Pharm Res 2015; 14(5):845-851 doi: 10.4314/tjpr.v14i5.15

© 2015 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: The current work validated a high performance liquid chromatography-tandem mass spectrometric (HPLC-MS/MS) bioassay method developed in-house for the quantitation of solifenacin in human plasma.
Methods: Solifenacin was extracted from plasma by a liquid-liquid extraction (LLE) technique using tert-butyl methyl ether. The dry extract was then reconstituted with 200 μL of the mobile phase (acetonitrile-water (80:20, v/v)). Solifenacin-d5 was the internal standard (IS). Elution was carried out on a C18 column at a flow rate of 1 mL/min. The MS/MS employed turbo-ion spray ionization in the positive ion mode. Solifenacin and IS were monitored at a mass to charge ratio (m/z) of 363.4 and 368.4, respectively. Bioassay validation followed International Bioanalytical Method Validation Guidelines.
Results: The validated calibration curves were linear over a range of 0.5 – 60.0 ng/mL (regression factors ≥ 0.9994). Method specificity was established in 6 different human plasma batches. Intra- and inter-day precision and accuracy were within ± 20 % (for lower limit of quantitation (LLOQ)) and ± 15 % (for low, mid and high quality control (QC) levels). Short- and long-term stability was within accepted range.
Conclusion: A specific, accurate and precise HPLC-MS/MS method has been validated for the determination of solifenacin in human plasma.

Keywords: Liquid extraction, Mass spectrometry, Solifenacin, Validation

Impact Factor
Thompson Reuters (ISI): 0.6 (2023)
H-5 index (Google Scholar): 49 (2023)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates