Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry

Syed S ul Hassan1, Syeda FA Zaidi1, Imran Tariq1 , Muhammad T Ansari2

1University College of Pharmacy, University of the Punjab, Lahore-54000; 2Department of Pharmacy, Bahaudin Zakariya University, Multan, Pakistan.

For correspondence:-  Imran Tariq   Email: imran1982@hotmail.com   Tel:00923224218583

Received: 3 August 2012        Accepted: 26 April 2013        Published: 12 June 2013

Citation: Hassan SS, Zaidi SF, Tariq I, Ansari MT. Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. Trop J Pharm Res 2013; 12(3):407-411 doi: 10.4314/tjpr.v12i3.20

© 2013 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with copper.
Method: A coloured complex based on UV/Vis spectroscopic method was developed for the determination of losartan potassium concentration in pharmaceutical formulations in the visible region. The colored complex of losartan was formed with cupric acetate (5:4). Analysis was carried out by the two methods - absorption ratio and calibration curve methods. The proposed method was validated in terms of linearity, accuracy and precision.
Results: The λ maximum of the complex was recorded at 530 nm.  Beer`s law was obeyed in the range of 10 - 50 µg/ml with a correlation coefficient (r2) of 0.9989. Mean analytical results from the calibration curve and absorption ratio methods were 99.42 and 99.16 % with relative standard deviation (RSD) of 0.97 and 0.82 %, respectively. Mean recovery was between 98.61 and 101.35 % and precision expressed as relative standard deviation (RSD) was 0.91 %.
Conclusion: The proposed method is simple, easy to apply, low-cost, and requires relatively inexpensive instruments. Thus, it is a suitable alternative to currently used spectrophotometric methods for the determination of losartan in bulk and solid dosage forms. 

Keywords: Losartan, Copper complex, Spectrophotometry, Validation

Impact Factor
Thompson Reuters (ISI): 0.6 (2023)
H-5 index (Google Scholar): 49 (2023)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates