Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Liquid Chromatography - Mass Spectrometry Method for the Simultaneous Determination and Confirmation of Seven Active Components in Chinese Medicine Kumu Injection

Zheng-Quan Lai1,2, Hui-Jun Liao1,2, Siu-Po Ip2, Yu-Yang Yi1, Shu-Jiang Shi1, Ji-Yan Su1,3, Xiao-Ping Lai1,3, Zi-Ren Su1 , Zhi-Xiu Lin2

1New Drug Research & Development Center, Guangzhou University of Chinese Medicine, Guangzhou, 510006; 2School of Chinese Medicine, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR; 3Dongguan Mathematical Engineering and Academy of Chinese Medicine, Guangzhou University of Chinese Medicine, Dongguan, 523808, PR China.

For correspondence:-  Zi-Ren Su   Email: suziren@gzucm.edu.cn   Tel:+862039358517

Received: 08 October 2013        Accepted: 20 November 2013        Published: 25 January 2014

Citation: Lai Z, Liao H, Ip S, Yi Y, Shi S, Su J, et al. Liquid Chromatography - Mass Spectrometry Method for the Simultaneous Determination and Confirmation of Seven Active Components in Chinese Medicine Kumu Injection. Trop J Pharm Res 2014; 13(1):141-148 doi: 10.4314/tjpr.v13i1.20

© 2014 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To develop and validate a simple and selective high performance liquid chromatography photo diode array mass spectrometry (HPLC-PDA-MS/MS) method for simultaneous determination and confirmation of seven major active alkaloids (6-Hydroxy-β-Carboline-1-carboxylic acid, β-Carboline-1-carboxylic acid, β-Carboline-1-propanoic acid, 3-Methylcanthin-5,6-dione, 4-Methoxy-3-methylcanthine-5,6-dione, 5-Hydroxy-4-methoxycanthin-6-one, 4,5-Dimethoxycanthin-6-one) in Kumu injections (KMIs).
Methods: For the analysis of the preparation, the optimal chromatographic condition was achieved on a Phenomenex Gemini C18 column with gradient elution of 25 mM aqueous ammonium acetate (pH = 4.0 adjusted by glacial acetate acid) and acetonitrile with @258;ow rate at 1.0 mL/min, column temperature at 35 oC and detection wavelengths at 245, 260 and 271 nm.
Results: Excellent linear behavior over the investigated concentration ranges was observed with regression coeffcient (R2) > 0.9997 for all analytes. Intra- and inter-day precisions for all studied constituents ranged from 0.20 to 1.80 %. Recoveries of the assayed constituents were in the range of 98.73 to 100.34 %. The results showed the contents of these seven marker compounds differed significantly among different batches of KMIs both from the same and different manufacturers.
Conclusion: The validated method was reliable, accurate, repeatable and can be applied to routine quality assessment of these active components in KMIs.

Keywords: Alkaloids, High performance liquid chromatography, Photo diode array, Mass spectrometry, Kumu injection, Quality control

Impact Factor
Thompson Reuters (ISI): 0.6 (2023)
H-5 index (Google Scholar): 49 (2023)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates