Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Combined diagnostic potential of multi-slice spiral CT and serum CRP levels in children with Mycoplasma pneumonia after azithromycin treatment

You Li1, Hui Lou1, Yang Cao1, Xing Huang1, Ye Zhang2

1Department of Radiology, The First People's Hospital of Chenzhou, Chenzhou 423000, Hunan Province, People's Republic of China; 2Pediatric Respiratory Department, The First People's Hospital of Chenzhou, Chenzhou 423000, Hunan Province, People's Republic of China.

For correspondence:-  Ye Zhang   Email: znnd35@163.com

Accepted: 27 May 2022        Published: 30 June 2022

Citation: Li Y, Lou H, Cao Y, Huang X, Zhang Y. Combined diagnostic potential of multi-slice spiral CT and serum CRP levels in children with Mycoplasma pneumonia after azithromycin treatment. Trop J Pharm Res 2022; 21(6):1263-1269 doi: 10.4314/tjpr.v21i6.19

© 2022 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To investigate the combined diagnostic value of multi-slice spiral computerized tomography (MSCT) and serum C-reactive protein (CRP) levels in children with mycoplasma pneumonia (MPP) after azithromycin treatment.  
Methods: Clinical data for 60 children with MPP who were treated in The First People's Hospital of Chenzhou, Chenzhou from February 2019 to February 2020, were retrospectively analyzed. All children were treated with azithromycin. Serum CRP levels were measured using immunoturbidimetric endpoint assay, while MSCT examination was done before and after treatment. This was a self-control clinical study in which the 60 patients served as their own controls. Thus, results obtained before treatment (control group, CG) were compared with those obtained after treatment (study group, EG). Within the same period, 60 healthy subjects were selected as the healthy group (HG), and were subjected to MSCT examination and serum CRP assay. The diagnostic results of CT were analyzed, and the responsiveness, selectivity, and positive and negative predictive values of the combination of MSCT and serum CRP levels were calculated.
Results: Pre-treatment serum CRP level was higher in CG than in EG and HG, and CRP level was higher in EG than in HG (p < 0.001). The MSCT imaging features of EG were significantly different from those of CG (p < 0.05). The probabilities of bronchial wall thickening, hilar and mediastinal lymphadenopathy and pleural effusion were significantly higher in CG than in EG (p < 0.05). The responsiveness, selectivity, and positive and negative predictive values of combination of MSCT and serum CRP in MPP children after azithromycin treatment were 70.0, 66.7, 67.7 and 69.0 %, respectively.  
Conclusion: The combination of MSCT examination and serum CRP levels resulted in high diagnostic efficiency, and it may be useful for monitoring MPP in children after azithromycin treatment. Therefore, the combined procedure may reduce the burden on families of MPP children by enhancing efficiency of diagnosis of the disease.

Keywords: Multi-slice spiral CT (MSCT), C-reactive protein (CRP), Azithromycin, Mycoplasma pneumonia

Impact Factor
Thompson Reuters (ISI): 0.6 (2023)
H-5 index (Google Scholar): 49 (2023)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates