Open Access


Read more
image01

Online Manuscript Submission


Read more
image01

Submitted Manuscript Trail


Read more
image01

Online Payment


Read more
image01

Online Subscription


Read more
image01

Email Alert



Read more
image01

Original Research Article | OPEN ACCESS

Determination of amino acids in black garlic using high-performance liquid chromatography after derivatization with 9-fluorenylmethyloxycarbonyl chloride

Ngoc-Van Thi Nguyen , Lan Hoang Vuong, Ngan Kim Huynh Nguyen, Nga Ngoc Thi Phan

College of Pharmacy, Can Tho University of Medicine and Pharmacy, 179 Nguyen Van Cu Street, An Khanh Ward, Ninh Kieu District, Can Tho City, Vietnam;

For correspondence:-  Ngoc-Van Nguyen   Email: ntnvan@ctump.edu.vn

Accepted: 28 October 2022        Published: 30 November 2022

Citation: Nguyen NT, Vuong LH, Nguyen NK, Phan NN. Determination of amino acids in black garlic using high-performance liquid chromatography after derivatization with 9-fluorenylmethyloxycarbonyl chloride. Trop J Pharm Res 2022; 21(11):2439-2445 doi: 10.4314/tjpr.v21i11.24

© 2022 The authors.
This is an Open Access article that uses a funding model which does not charge readers or their institutions for access and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0) and the Budapest Open Access Initiative (http://www.budapestopenaccessinitiative.org/read), which permit unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited..

Abstract

Purpose: To quantify the amino acids obtained from black garlic (Allium sativum L.) using high-performance liquid chromatography after derivatization with 9-fluorenylmethyloxycarbonyl chloride (FMOC-Cl).
Methods: Homogenized black garlic samples were derivatized with 9-fluorenylmethyloxycarbonyl chloride (FMOC-Cl) reagent in borate buffer at 30 °C for 60 min. The black garlic samples were hydrolyzed with 5.0 mL HCl (6 N) and neutralized to pH 5 – 6 by adding 30 mL NaOH (1 N). Amino acids were measured using high-performance liquid chromatography coupled with a fluorescence detector after hydrolysis and derivatization with FMOC-Cl reagent. Gradient elution mixture consisted of acetonitrile, methanol, and water at a flow rate of 1.0 mL/min, 0.2 % ammonium acetate, and 0.1 % formic acid.
Results: The ranges of the limits of detection and quantification were 30 and 100 g/mL, respectively. The overall intra- and inter-day variations (%RSD) for the precision findings were smaller than 3.43 and 4.63 %, respectively. The accuracy of the developed method was good, ranging from 90.9 to 106.8 %. The amino acids of six black garlic products from the market were determined using the suggested approach. The findings indicated that glutamic acid, the main amino acid, is present in the maximum concentration (564.64 – 1333.9 mg/100 g) in black garlic.
Conclusion: The validated method is for the determination of the amino acids in black garlic and would be a helpful tool for the quality control of products containing black garlic.

Keywords: Amino acid, Black garlic, Derivatization, High-performance liquid chromatography (HPLC), 9-fluorenylmethyloxycarbonyl chloride (FMOC-Cl)

Impact Factor
Thompson Reuters (ISI): 0.6 (2023)
H-5 index (Google Scholar): 49 (2023)

Article Tools

Share this article with



Article status: Free
Fulltext in PDF
Similar articles in Google
Similar article in this Journal:

Archives

2024; 23: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10
2023; 22: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2022; 21: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2021; 20: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2020; 19: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2019; 18: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2018; 17: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2017; 16: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2016; 15: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2015; 14: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2014; 13: 
1,   2,   3,   4,   5,   6,   7,   8,   9,   10,   11,   12
2013; 12: 
1,   2,   3,   4,   5,   6
2012; 11: 
1,   2,   3,   4,   5,   6
2011; 10: 
1,   2,   3,   4,   5,   6
2010; 9: 
1,   2,   3,   4,   5,   6
2009; 8: 
1,   2,   3,   4,   5,   6
2008; 7: 
1,   2,   3,   4
2007; 6: 
1,   2,   3,   4
2006; 5: 
1,   2
2005; 4: 
1,   2
2004; 3: 
1
2003; 2: 
1,   2
2002; 1: 
1,   2

News Updates