Indexed by Science Citation Index (SciSearch), International Pharmaceutical Abstract, Chemical Abstracts, Embase, Index Copernicus, EBSCO, African Index Medicus, JournalSeek, Journal Citation Reports/Science Edition, Directory of Open Access Journals (DOAJ), African Journal Online, Bioline International, Open-J-Gate

ISSN: 1596-5996 (print); 1596-9827 (electronic)-


Home | Back Issues | Current Issue | Review manuscript | Submit manuscript

 
 

This Article

 

Abstract

 

Full-Text (PDF)

 

Table of contents

 

Comments

 

Letters

 

Comments to Editor

 

e-mail Alert

 

Sign Up

 

Research Article


 

Development and Validation of a Bioanalytical Method for Direct Extraction of Diclofenac Potassium from Spiked Plasma

 

Attia Sarfraz1,2*, Muhammad Sarfraz1,2 and Mahmood Ahmad1

1Faculty of Pharmacy and Alternative Medicines, The Islamia University of Bahawalpur, 2Department of Pharmacy, The University of Lahore, Pakistan.

 

For correspondence: E-mail: attia@uol.edu.pk, chiefpharm@gmail.com Tel: (92) 62-9255243, 300-6986234; Fax: (92) 62-9255565

z

Received: 16 January 2011                                                     Revised accepted: 14 August 2011

 

Tropical Journal of Pharmaceutical Research, Oct 2011; 10(5): 663-669

http://dx.doi.org/10.4314/tjpr.v10i5.16

  

Abstract

 

Purpose: To develop and validate a user-friendly spiked plasma method for the extraction of diclofenac potassium that reduces the number of treatments with plasma sample, in order to minimize human error.

Method: Instead of solvent evaporation technique, the spiked plasma sample was modified with H2SO4 and NaCl, respectively, and then the drug was extracted after vortexing the sample with acetonitrile as precipitating agent. The separation of diclofenac potassium and internal standard (ketoprofen) was achieved at preset conditions: 5 μm ODS Hypersil C-18 (4.0 mm x 250 mm) column, eluted with 50% acetonitrile in water (v/v) as mobile phase containing ammonium acetate and triethylamine (TEA), at a flow rate of 1 mL min-1.

Results: The peaks of the drug and internal standard (I.S.) were resolved at 14 ± 1 min and 7 ± 1 min, respectively. The calibration curve and linearity were determined over the concentration range of 0.25 to 40 µg mL-1 and they were linear (r2 = 0.9991 and 0.9982, respectively). The accuracy was > 81.32 %. Limit of detection and limit of quantification were 0.05 and 0.25 µg mL-1, respectively, while the recovery range for diclofenac potassium and ketoprofen was more than 79 and 85 %, respectively. The absolute average difference of 0.18 between the observed concentrations for intra- and inter-day studies indicated that the sample was stable for over one month.

Conclusion: The proposed method may be applied to routine bioanalysis, particularly for NSAIDs, due to its high sensitivity, specificity, repeatability, reproducibility, robustness and ruggedness.

 

Keywords: Bioanalytical method, Diclofenac potassium, RP-HPLC method, NSAIDs, Plasma

Copyright@2002-2010. Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City. All rights reserved.

Powered by Poracom E-mail: jmanager@poracom.net