Indexed by Science Citation Index (SciSearch), International Pharmaceutical Abstract, Chemical Abstracts, Embase, Index Copernicus, EBSCO, African Index Medicus, JournalSeek, Journal Citation Reports/Science Edition, Directory of Open Access Journals (DOAJ), African Journal Online, Bioline International, Open-J-Gate

ISSN: 1596-5996 (print); 1596-9827 (electronic)-


Home | Back Issues | Current Issue | Review manuscript | Submit manuscript

 
 

This Article

 

Abstract

 

Full-Text (PDF)

 

Table of contents

 

Comments

 

Letters

 

Comments to Editor

 

e-mail Alert

 

Sign Up

 

Original Research Article


Simultaneous Determination of Co-formulated Matrine and Secnidazole in Suppositories by Reverse Phase High Performance Liquid Chromatography 

Haixia Lv, Suying Ma*, Xiao Wang and Xiaojun Shang

School of Pharmacy, Xinxiang Medical University, Xinxiang Henan, 453003, PR China 

*For correspondence: Email: suyingma@163.com  Tel: + 86-373-3029879 

Received:  20 February 2012                                                               Revised accepted: 28 March 2013

Tropical Journal of Pharmaceutical Research, June 2013; 12(3): 413-418

http://dx.doi.org/10.4314/tjpr.v12i3.21       

Abstract

 

Purpose: To develop and validate a new, simple, sensitive and accurate high performance liquid chromatographic (HPLC) method for the simulataneous determination of matrine and secnidazole in suppositories.

Methods: The method involved using a SinoChoom ODS-BP C18 column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile–triethylamine (0.05 %) in 0.025 mol/L KH2PO4 (20:80, v/v). The flow rate was 1 mL/min and detection was monitored at 210 and 311 nm for matrine and secnidazole, respectively. Total run time was 10 min and the column was maintained at 35 oC. 

Results: The excipients in the suppository did not interfere with the drug peaks. Matrine was eluted at a retention time (RT) of 4.30 min while linearity for the quantification of drug was obtained in the concentration range of 10.0 - 100.0 µg/mL (r2 = 0.9991). Secnidazole was eluted at a retention time (tr) of 6.69 min and linearity for the quantification of the drug was obtained in the concentration range of 10.0 - 150.0 µg/mL (r2 = 0.9993). Intra- and inter-day variations were < 1.0 % for both matrine and secnidazole.

Conclusion: The developed HPLC method was validated according to International Conference on Harmonisation (ICH) guidelines and proved to be suitable for the simultaneous determination of matrine and secnidazole in suppositories.

 

Keywords: Matrine, Secnidazole, Suppository, HPLC, Assay

Copyright@2002-2010. Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City. All rights reserved.

Powered by Poracom E-mail: jmanager@poracom.net