Indexed by Science Citation Index (SciSearch), International Pharmaceutical Abstract, Chemical Abstracts, Embase, Index Copernicus, EBSCO, African Index Medicus, JournalSeek, Journal Citation Reports/Science Edition, Directory of Open Access Journals (DOAJ), African Journal Online, Bioline International, Open-J-Gate

ISSN: 1596-5996 (print); 1596-9827 (electronic)-


Home | Back Issues | Current Issue | Review manuscript | Submit manuscript

 
 

This Article

 

Abstract

 

Full-Text (PDF)

 

Table of contents

 

Comments

 

Letters

 

Comments to Editor

 

e-mail Alert

 

Sign Up

 

Original Research Article


 

Accumulation of 99mTC-Methylene Diphosphonate Radiotracer in Rat's Forelimb

Gh Assadnassab

Department of Clinical Science, Faculty of Veterinary Medicine, Tabriz Branch, Islamic Azad University, Tabriz, Iran

 

*For correspondence: Email: assadnassabgh@iaut.ac.ir; Tel: +98 914 412 1145

 

Received: 7 December 2013                                                                  Revised accepted: 22 September 2014

 

Tropical Journal of Pharmaceutical Research, November 2014; 13(11): 1899-1902

http://dx.doi.org/10.4314/tjpr.v13i11.18   

Abstract

 

Purpose: To evaluate the efficacy and radioactivity counts of technetium-99m methylene diphosphonate (99mTc-MDP) radiotracer by scintigraphy.

Method: In this study, 7 healthy Wistar rats were anesthetized. Technetium was milked from molybdenum-technetium generator and added to methylene diphosphonate (MDP) kit. Scintigraphic scans were carried out in several areas of the rat’s forelimbs by gamma camera 2 h after the injection of 99mTc-MDP via the tail vein. Accumulations of the radioisotope in the study areas were calculated using region of interest (ROI) technique.

Results: Mean count of radioisotope in the right and left sides of the shoulder area was 4179.29 and 4074.24, respectively; in the right and left sides of the elbow joint areas, the count was 1662.14, 1645.28, respectively. The count in the right and left sides of the carpal joint and finger areas was 1908.42 and 2028.28, respectively.

Conclusion: This study shows that 99mTc-MDP radiotracer can be used for survey radioactivity examination in different bones of the forelimb. Comparison of radioisotope counts in these areas can be used for the diagnosis of disease.

 

Keywords: Bone, Rat, Scintigraphy, Technetium, Methylene diphosphonate

Copyright@2002-2010. Pharmacotherapy Group, Faculty of Pharmacy, University of Benin, Benin City. All rights reserved.

Powered by Poracom E-mail: jmanager@poracom.net